Posted : Monday, January 01, 2024 04:27 PM
*Key Responsibilities:*
* *Backflow Preventer Valve Replacement:*
* Execute the removal and replacement of backflow preventer valves in accordance with project specifications and regulatory requirements.
* Follow established procedures and safety protocols to ensure the proper installation and alignment of new valves.
* *Tightness Testing:*
* Perform tightness tests on the replaced valves to verify their integrity and functionality.
* Adhere to strict standards for allowable leakage, ensuring that systems meet or exceed specified performance criteria.
* *System Integrity Testing:*
* Conduct system integrity tests on disturbed piping using nominal operating system pressure and temperature.
* Ensure that the system remains leak-free under operational conditions, with zero allowable leakage.
* *Reporting and Documentation:*
* Prepare comprehensive reports detailing the results of system integrity tests and tightness tests.
* Submit reports to the supervisor in either hard copy or electronic format, ensuring legibility and accuracy.
* *Surface Protection:*
* Implement surface protection measures as per regulatory requirements (e.
g.
, 009-32 of 2.
1) for all new and disturbed surfaces.
* Adhere to established procedures to prevent contamination and ensure the long-term integrity of system components.
*Qualifications:*
* Proven experience in plumbing, pipefitting, or related field, with a focus on backflow prevention systems.
* Familiarity with industry standards and regulatory guidelines governing backflow prevention and valve replacement procedures.
* Strong mechanical aptitude and proficiency in tools and equipment used for valve installation and testing.
* Detail-oriented with a commitment to precision and accuracy in all tasks.
* Excellent communication skills and the ability to work collaboratively in a team environment.
* Certification as a Backflow Prevention Assembly Tester (BPAT) or equivalent preferred.
*Education and Experience:*
* High school diploma or equivalent required; additional vocational training or certification in plumbing or pipefitting preferred.
* Minimum of [X] years of experience in backflow preventer valve replacement or related field.
*Physical Requirements:*
* Ability to lift heavy equipment and work in physically demanding environments.
* Comfort working at heights and in confined spaces.
* Stamina to perform tasks for extended periods under varying environmental conditions.
Job Type: Full-time
Pay: $45,041.
00 - $50,328.
00 per year
Benefits:
* 401(k)
* 401(k) matching
* Dental insurance
* Health insurance
* Life insurance
* Paid time off
* Vision insurance
Schedule:
* 8 hour shift
* Monday to Friday
Supplemental pay types:
* Bonus opportunities
* Commission pay
* Signing bonus
* Tips
Ability to Relocate:
* Jbphh, HI 96860: Relocate before starting work (Required)
Work Location: In person